BSWTS - RP 4033 RESIN PT A
- MSDS: BSWTS
- Manufacturer: CIBA GEIGY CORP
- Product Name: RP 4033 RESIN PT A
- National Stock Number: 8030-00N047800
Product Identification
Product ID:RP 4033 RESIN PT A
MSDS Date:05/30/1989
FSC:8030
NIIN:00N047800
MSDS Number: BSWTS
Responsible Party
HAWTHORNE, NY 10532
US
Emergency Phone: 800-888-8372
Info Phone: 914-785-2000
Cage: 07566
Contractor
Telephone: 800-888-8372
Cage: 07566
Ingredients
7-OXABICYCLO (4.1.0) HEPTANE, 3-(EPOXYETHYL)-;
CAS: 106-87-6
RTECS: RN8640000
OSHA PEL N/K
ACGIH TLV: N/K
CALCIUM CARBONATE
CAS: 1317-65-3
RTECS: EV9580000
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
ALUMINUM (SARA III)
CAS: 7429-90-5
RTECS: BD0330000
OSHA PEL 15MG/M3 DUST;5 FUME
ACGIH TLV: 10 MG/M3 DUST
ALUMINUM HYDROXIDE; (ALUMINUM OXIDE TRIHYDRATE)
CAS: 21645-51-2
RTECS: BD0940000
OSHA PEL N/K
ACGIH TLV: N/K
EPOXY RESIN
CAS: 25068-38-6
RTECS: KC2100000
OSHA PEL N/K
ACGIH TLV: N/K
EPOXY PHENOL NOVOLAC RESIN; (EPOXY PHENOLIC NOVOLAC)
CAS: 28064-14-4
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN: IRRITANT. EYE: IRRITANT.
SENSITIZATION: POSSIBLE IN SUSCEPTIBLE INDIVIDUALS. OVEREXP: EYE,
SKIN & RESP IRRIT. SKIN SENSIT IN SUSCEPTIBLE INDIVIDUALS.
ABSORPTION THROUGH SKIN MAY CAUSE NAUSEA, VO MITING & OTHER SIGNS
OF ILLNESS. OVEREXP-CHRONIC: (VINYL CYCLOHEXENE DIOXIDE) SKIN
PAINTING TESTS IN (EFTS OF OVEREXP)
Explanation of Carcinogenicity:VINYL CYCLOHEXENE DIOXIDE: NTP 6TH
ANNUAL REPORT ON CARCINOGENS 1991: ANTICIPATED TO BE CARCINOGEN.
Effects of Overexposure:HLTH HAZ: ANIMALS CAUSED SKIN CANCERS, BUT NO
CANCERS HAVE BEEN REPORTED IN HUMANS.
Medical Cond Aggravated by Exposure:SKIN AND EYE CONDITIONS.
First Aid
First Aid:SKIN:WASH W/SOAP & WATER. REMOVE CONTAM CLTHG & LAUNDER
BEFORE REUSE. INGEST: GIVE PLENTY OF WATER TO DRINK. DO NOT INDUCE
VOMIT. CALL MD. INHAL: REMOVE TO FRESH AIR. GIVE OXYGEN &/OR ARTF
RESP, IF NE EDED. CALL MD. REFERRAL TO MD IS RECOMMENDED IF THERE
IS ANY QUESTION ABOUT SERIOUSNESS OF INJURY. EYE:IMMED FLUSH
W/POTABLE WATER FOR A MINIMUM OF 15 MIN. SEEK ASSISTANCE FROM MD .
Fire Fighting
Flash Point Method:PMCC
Flash Point:255F,124C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:DECOMPOSITION AND COMBUSTION PRODUCTS MAY
BE TOXIC.
Accidental Release
Spill Release Procedures:REMOVE SPILLAGE BY ABSORBING IN ABSORBENT
MATL, DISPOSE OF IN CLOSED CNTNR. FLUSH CONTAMINATED AREA WITH
WATER. COLLECT WATER FOR PROPER DISPOSAL. AVOID CONTACT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NUISANCE DUST MAY BE GENERATED WHEN
SANDING OR SAWING CURED MATL.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED ORGANIC VAPOR CARTRIDGE
RESPIRATOR WHEN VAPOR/MIST EXPOSURE IS LIKELY.
Ventilation:GENERAL MECHANICAL AND LOCAL EXHAUST IN ACCORDANCE WITH
ACGIH RECOMMENDATIONS.
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:WEAR SPLASH-PROOF CHEMICAL GOGGLES.
Other Protective Equipment:PROTECTIVE CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:>400F,>204C
Vapor Pres:<0.4 @ 52C
Spec Gravity:1.7-1.8(H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:NEGLIG
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, ACIDS AND BASES.
Stability Condition to Avoid:EXCESSIVE HEAT FOR PROLONGED PERIODS OF
TIME.
Hazardous Decomposition Products:COMBUSTION MAY FORM TOXIC MATERIALS,
SUCH AS CARBON DIOXIDE, CARBON MONOXIDE.
Disposal
Waste Disposal Methods:CONSULT QUALIFIED LOCAL OR CORPORATE PERSONNEL
FOR METHOD THAT WILL COMPLY WITH LOCAL, STATE AND FEDERAL HEALTH
AND ENVIRONMENTAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.